Edit it in Health Facility Briefing System (HFBS) | |||
---|---|---|---|
![]() |
Edit this room data or print a PDF using the HFBS - Health Facility Briefing System. Customise this room data for your project, or add it to an existing health facility brief in HFBS Briefing Module. | Edit Briefing |
Room Layout Sheet | |||
---|---|---|---|
![]() |
Download a PDF Room Layout Sheet (RLS) for this standard component. | Free | View |
Other Files | |||
---|---|---|---|
![]() |
Buy an edible AutoCAD DWG Room Layout Sheet (RLS) for this standard component. | $2.99 |
Online Room Data Sheet |
---|
Room Code | OR-VC-I |
Net Room Area Briefed | 65 |
Hours of Operation | 24 Hours |
Occupancy | 1 patient; 5 - 12 staff |
Description / Special Requirements | The Operating Room - Vascular/ Cardiac provides an aseptic environment in which to carry out surgical procedures under local, regional or general anaesthetic. The Vascular/ Cardiac OR will include Angiography imaging equipment. Cardiac Protected electrical area Special Air Conditioning - HEPA filtration Additional Design Considerations: - Minimum critical dimension 6000mm. - 'Laser In Use' warning lights may be required outside all exit doors to room if laser equipment is to be used - Lead shielding will be required; to be assessed by Radiation Consultant - External windows are desirable - double glazed with integral Venetian blinds - Provide isolated power supply individually to each large Operating Room, together with its associated line isolation and overload monitors |
Amendment | 24.10.10, - First Draft |
ID | Fabric | Material | Finish | Specification | Selection | Remarks |
2000 | Skirting | Vinyl | Prefinished | Floor vinyl coved, 150mmH | ||
3010 | Wall finish | Paint | Scrub resistant | |||
3038 | Wall finish | Vinyl | Prefinished | Wall vinyl to 900 AFFL | ||
5010 | Ceiling | Plasterboard | Paint, washable | Flush set, suspended | ||
8010 | Door protection | Composite | Prefinished PVC | Protection plate to 900 AFFL | Equal to 'Acrovyn' | |
8040 | Door protection | Composite | Prefinished PVC | To door frame | Equal to 'Acrovyn' | |
9232 | Doors | Solid Core/ Glass | Paint | Double leaf, with lead sheilding, lead glass observation panel | 1500 min clear opening to patient entry/exit | |
9004 | Doors | Solid Core/ Glass | Paint | Single leaf, observation panel | 920mm clear opening, to Control Room | |
7025 | Observation | Lead glass | Clear | Internal window | ||
7001 | Windows | external; with integral venetians | ||||
8001 | Door protection | Vinyl | Prefinished | To 900AFFL | ||
1000 | Floor finish | Vinyl | Standard slip resistant | Seamless, coved | ||
6015 | Cornice | Plasterboard | Paint | Flush coved between wall & ceiling | ||
7026 | Observation | Lead Glass | Clear | Through door/s | with sliding cover |
ID | Description | Category | Group | Qty | Selection / Remarks |
150 | Air flowmeter | Furniture/ Fitting | 3 | 2 | to services on pendant |
300 | Trolley: anaesthetic | Furniture/ Fitting | 3 | 1 | |
1252 | Blind: Venetian integral | Furniture/ Fitting | 1 | 1 | to internal & external window, if provided |
1440 | Bowl stand: single | Furniture/ Fitting | 3 | 2 | |
1580 | Chair: anaesthetist | Furniture/ Fitting | 3 | 1 | |
4450 | Cupboard: endoscope hanging | Furniture/ Fitting | 3 | 5 | |
5900 | Desk | Furniture/ Fitting | 2 | 1 | write-up Desk |
6152 | Dispenser: disposable glove | Furniture/ Fitting | 2 | 1 | |
6410 | Documentation Station | Furniture/ Fitting | 2 | 1 | built in |
8390 | Trolley: gowns | Furniture/ Fitting | 3 | 1 | |
10200 | Trolley: instrument | Furniture/ Fitting | 3 | 3 | |
11100 | IV stand: mobile | Furniture/ Fitting | 3 | 2 | |
11500 | Kickbucket & stand | Furniture/ Fitting | 3 | 2 | |
12300 | Linen carrier: dirty, single | Furniture/ Fitting | 3 | 1 | |
13500 | Table: mayo | Furniture/ Fitting | 3 | 1 | |
16250 | Oxygen flowmeter | Furniture/ Fitting | 3 | 4 | to services on pendant |
21730 | Stool: operating, mobile | Furniture/ Fitting | 3 | 2 | |
21950 | Suction adapter | Furniture/ Fitting | 3 | 4 | to services on pendant |
22000 | Suction bottle | Furniture/ Fitting | 3 | 4 | in mobile carrier |
22050 | Suction bottle carrier | Furniture/ Fitting | 3 | 1 | |
24400 | Whiteboard | Furniture/ Fitting | 2 | 1 | 900 x 900 |
24440 | Workstation: computer | Furniture/ Fitting | 2 | 1 | recessed cabinet |
ID | Description | Grp | Qty | Ele | Data | CdW | HtW | WmW | Tap | Dns | Gas | Selection / Remarks |
700 | Anaesthetic machine | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | |
1002 | iPod docking: wall mounted | 2 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | part of Doc Station |
1003 | Camera: PTZ | 2 | 4 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | |
9750 | Clock: slave, analogue | 1 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | master clock system |
9800 | Clock: time elapse | 1 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | beside analogue |
11400 | Computer: PC & monitor | 3 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | to Doc Station |
16000 | Diathermy machine | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | |
32800 | Light: operating, 2 arm, 550/550 diam nominal | 1 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | |
35950 | Monitor | 2 | 1 | yes | opt | ___ | ___ | ___ | ___ | ___ | ___ | touch panel; part of Doc Station |
35960 | Monitor: anaesthetic | 3 | 1 | yes | opt | ___ | ___ | ___ | ___ | ___ | ___ | with printer, on anaesth machine |
36125 | Monitor: dual flat panel | 2 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | |
36670 | Operating table: mobile, electric | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | floor rails as per room layout sheet |
36135 | Monitor: quad flat panel | 2 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | |
47000 | Services pendant: ceiling | 2 | 2 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | |
54520 | Telephone: handset, handsfree | 3 | 1 | ___ | yes | ___ | ___ | ___ | ___ | ___ | ___ | on bench |
56800 | Television: large screen | 2 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | LCD screens; fitted and sealed to wall; reinforce wall to support 65kg weight |
58650 | IMG: Angiography- vascular imaging unit | 3 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | |
68800 | Xray viewer: 3 screen | 1 | 2 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | recessed |
ID | Description | Service Category | Qty | Selection / Remarks |
1017 | Hospital LAN | Communications | 3 | to Documentation Station |
1017 | Hospital LAN | Communications | 2 | to services pendant |
1120 | Monitor connection facilities and cabling | Communications | to wall TV monitor | |
1379 | Audio/ Video outlet | Communications | 1 | to Documentation Station |
1379 | Audio/ Video outlet | Communications | 2 | to services pendant |
1386 | Voice / Data outlet: analogue telephone | Communications | 1 | to Documentation Station |
5005 | Air conditioning: special | HVAC | HEPA filtered | |
5040 | Pressure: positive | HVAC | ||
6001 | General: colour corrected | Lighting | variable lighting level, dimmable | |
6074 | Special: 'Laser In Use' lights | Lighting | outside room entries, if laser to be used | |
6076 | Special: 'X-ray In Use' lights | Lighting | 1 | outside room entries |
7000 | Oxygen (O2) | Medical Gases | 4 | to services pendant |
7010 | Nitrous Oxide (N2O) | Medical Gases | 2 | to services pendant |
7020 | Medical Air (MA) | Medical Gases | 2 | to services pendant |
7030 | Tool Air | Medical Gases | 2 | to services pendant |
7040 | Suction | Medical Gases | 4 | to services pendant |
7050 | Gas Alarm Panel | Medical Gases | 1 | |
7060 | Tourniquet air | Medical Gases | 1 | and controls, to wall, optional |
7062 | Tool Air: unregulated | Medical Gases | 2 | to services pendant |
7070 | Scavenge | Medical Gases | 2 | to services pendant |
8010 | Staff/ Nurse assist call | Nurse Call | 1 | + indicator button & light |
8080 | Emergency call | Nurse Call | 1 | + indicator button & light |
8090 | Orderly/ Porter call | Nurse Call | 1 | |
9000 | GPO: Single | Power | 3 | to services panel |
9010 | GPO: Emergency power, single | Power | 1 | for TV wall monitor |
9010 | GPO: Emergency power, single | Power | 3 | to services panel |
9011 | GPO: Emergency power, double | Power | 5 | to Documentation Station |
9011 | GPO: Emergency power, double | Power | 6 | to services pendant |
9014 | GPO: UPS, double | Power | 6 | to services pendant |
9014 | GPO: UPS, double | Power | 4 | to Documentation Station |
9015 | GPO: Cleaner | Power | 1 | |
9016 | GPO: UPS, special | Power | 2 | to services pendant |
9016 | GPO: UPS, special | Power | 2 | to services pendant |
9017 | Direct power (Essential Power), 10 amp | Power | 2 | to services pendant |
9022 | Isolated power supply system | Power | individually to each OR | |
9024 | Line isolation monitor | Power | to each OR | |
9026 | Overload monitor | Power | to each OR | |
9030 | Cardiac protected/ IPS | Power | ||
9050 | Direct connection | Power | 8 | to clocks, operating lights & XRV; refer to manufacturers' specifications |
11000 | Wall panel | Services Panels | 4 |