Print Download PDF Version
Bay - Drinking Fountain,1m2
Room Code
BDF-1-I
Net Room Area Briefed
1
Hours of Operation
Available 24 Hours
Occupancy
1 intermittently
Description / Special Requirements
An accessible, recessed Drinking Fountain bay for patient, staff and public use. The bay should be associated with a a public waiting area or Main Entry/ lobby area.
Amendment
24.10.10, - First Draft.
22.04.15, - Room Name, Description,and FFE modified.
Fabric and outline specifications
ID
Fabric
Material
Finish
Specification
Selection
Remarks
3000
Wall finish
Paint
Acrylic, washable
4031
Wall protection
Composite
Prefinished PVC
Corner guards to 1500 AFFL
other heights also acceptable as per project standardisation
5060
Ceiling
Acoustic
Prefinished
Drop-in tiles, 600x1200
consistent with adjacent area
6025
Cornice
Aluminium
Powdercoat
shadow line
consistent with adjacent area
1000
Floor finish
Vinyl
Standard slip resistant
Seamless, coved
consistent with adjacent area
2000
Skirting
Vinyl
Prefinished
Floor vinyl coved, 150mmH
consistent with adjacent area
3060
Wall finish
Vinyl
Prefinished
Splashback
other waterproof splashback also acceptable
5007
Ceiling
Plasterboard
Paint
Bulkhead
Fittings and Furniture (FF)
ID
Description
Category
Group
Qty
Selection / Remarks
5824
Waste bin: paper
Furniture/ Fitting
3
1
6180
Dispenser: disposable cup
Furniture/ Fitting
2
2
Fixtures, Equipment and associated Services (FE)
ID
Description
Grp
Qty
Ele
Data
CdW
HtW
WmW
Tap
Dns
Gas
Selection / Remarks
18100
Drinking fountain
1
2
___
___
yes
___
___
yes
yes
___
1 - at accessible height
Services
ID
Description
Service Category
Qty
Selection / Remarks
5000
Airconditioning
HVAC
consistent with adjacent area
1983
General fluorescent: downlights
Lighting
recessed