Bay - Flowers, Enclosed

Room Code BFLW-ENC-I
Net Room Area Briefed 4
Hours of Operation 24 Hours
Occupancy 1 intermittently
Description / Special Requirements A room with bench and sink for use by staff and volunteers to maintain patients' flowers. The room will have direct access to the Unit corridor. Acoustics: Acoustic privacy required
Amendment 24.10.10, - First Draft 21.04.11, - FF modified

Fabric and outline specifications

ID Fabric Material Finish Specification Selection Remarks
1000 Floor finish Vinyl Standard slip resistant Seamless, coved
2000 Skirting Vinyl Prefinished Floor vinyl coved, 150mmH
3000 Wall finish Paint Acrylic, washable
8010 Door protection Composite Prefinished PVC Protection plate to 900 AFFL As required
8040 Door protection Composite Prefinished PVC To door frame As required
9004 Doors Solid Core/ Glass Paint Single leaf, observation panel 920mm clear opening, lockable
3022 Wall finish Resinate, 6mm Prefinished Splashback tiles also acceptable
6025 Cornice Aluminium Powdercoat shadow line
5060 Ceiling Acoustic Prefinished Drop-in tiles, 600x1200

Fittings and Furniture (FF)

ID Description Category Group Qty Selection / Remarks
1050 Bench: laminate Furniture/ Fitting 1 1 open under part for bin
4410 Cupboard: under bench Furniture/ Fitting 1 1 adjustable shelf
6154 Dispenser: paper/ hand towel Furniture/ Fitting 2 1 to sink
6156 Dispenser: soap Furniture/ Fitting 2 1 to sink
20000 Shelving unit: adjustable Furniture/ Fitting 1 1 above bench for storing vases
24102 Waste bin: general Furniture/ Fitting 3 1

Fixtures, Equipment and associated Services (FE)

ID Description Grp Qty Ele Data CdW HtW WmW Tap Dns Gas Selection / Remarks
47890 Sink & drainer: single, 930mmL 1 1 ___ ___ yes opt opt yes yes ___ short lever taps, warm water

Services

ID Description Service Category Qty Selection / Remarks
5000 Airconditioning HVAC
2189 General LED Lighting
2577 PO: Double Power 1 Above bench