1 Bed Room - Standard, 18m2, Outboard Ensuite

Room Code BFLW-OP-I
Net Room Area Briefed 2
Hours of Operation 24 Hours
Occupancy 1 intermittently
Description / Special Requirements Area with bench and sink for use by staff and volunteers to maintain patients' flowers. The Flower Bay will have direct access to the Unit corridor. Acoustics: Acoustic privacy required
Amendment 24.10.2010 First Draft 03.09.2014 Modifications to Selection/ Remarks for Room Fabric, FF, FE

Fabric and outline specifications

ID Fabric Material Finish Specification Selection Remarks
1000 Floor finish Vinyl Standard slip resistant Seamless, coved
3000 Wall finish Paint Acrylic, washable
5060 Ceiling Acoustic Prefinished Drop-in tiles, 600x1200
3022 Wall finish Resinate, 6mm Prefinished Splashback tiles also acceptable
6025 Cornice Aluminium Powdercoat shadow line
2000 Skirting Vinyl Prefinished Floor vinyl coved, 150mmH
4031 Wall protection Composite Prefinished PVC Corner guards to 1500mm AFFL

Fittings and Furniture (FF)

ID Description Category Group Qty Selection / Remarks
1050 Bench: laminate Furniture/ Fitting 1 1 open under part for bin
4410 Cupboard: under bench Furniture/ Fitting 1 1 adjustable shelves
4460 Cupboard: wall mounted Furniture/ Fitting 1 1 over bench, adjustable shelf
6154 Dispenser: paper/ hand towel Furniture/ Fitting 2 1 to sink
6156 Dispenser: soap Furniture/ Fitting 2 1 to sink
20000 Shelving unit: adjustable Furniture/ Fitting 1 1 above bench for storing vases
24102 Waste bin: general Furniture/ Fitting 3 1 under bench

Fixtures, Equipment and associated Services (FE)

ID Description Grp Qty Ele Data CdW HtW WmW Tap Dns Gas Selection / Remarks
47890 Sink & drainer: single, 930mmL 1 1 ___ ___ yes opt opt yes yes ___ mixer tap; warm water

Services

ID Description Service Category Qty Selection / Remarks
5000 Airconditioning HVAC
6000 General fluorescent Lighting
9001 GPO: Double Power 1 Above bench