A recessed bay to provide supervised holding of the resuscitation trolley and equipment. The bay should be located close to a Staff Station and under staff observation.
Special Design Requirements: The Bay should not impede corrior access.
Amendment
24.10.2010 First Draft
02.09.2014 Description, FE updated.
29.10.2014 Fabric modified.
18.08.2016 Room Fabric & Services updated
Fabric and outline specifications
ID
Fabric
Material
Finish
Specification
Selection
Remarks
1000
Floor finish
Vinyl
Standard slip resistant
Seamless, coved
2000
Skirting
Vinyl
Prefinished
Floor vinyl coved, 150mmH
5010
Ceiling
Plasterboard
Paint, washable
Flush set, suspended
6025
Cornice
Aluminium
Powdercoat
shadow line
4020
Wall protection
Composite
Prefinished PVC
Crash rail at 900AFFL
3000
Wall finish
Paint
Acrylic, washable
5007
Ceiling
Plasterboard
Paint
Bulkhead
4031
Wall protection
Composite
Prefinished PVC
Corner guards to 1500mm AFFL
other heights also acceptable as per project standardisation