Room Code | ENDP-I |
Net Room Area Briefed | 36 |
Hours of Operation | 24 Hours |
Occupancy | 1 patient; 3 - 5 staff |
Description / Special Requirements | Operating Room/ Procedures Room for minor surgical or endoscopic procedures under local, regional or general anaesthetic in an aseptic environment. A clinical scrub basin or sink will be located immediately outside the room. Clean-up, scrub and Set-up rooms may be located in close proximity. Cardiac Protected electrical area Special Air Conditioning - HEPA filtration Additional Design Considerations: - 'Laser/XRay in use' warning lights may be required outside all exit doors to room if laser/XRay equipment is to be used - Lead shielding may be required depending on use of X-ray equipment; to be assessed by Radiation Authority - External windows desirable |
Amendment | 28.05.2014 - First Draft |
ID | Fabric | Material | Finish | Specification | Selection | Remarks |
8010 | Door protection | Composite | Prefinished PVC | Protection plate to 900mm AFFL | ||
8040 | Door protection | Composite | Prefinished PVC | To door frame | ||
9127 | Doors | Solid Core/ Safety glass | Paint | 1 1/2 leaf, observation panel | 1600mm clear opening topatient entry/ exit; obspanel with sliding cover or integral venetians | |
1000 | Floor finish | Vinyl | Standard slip resistant | Seamless, coved | ||
9006 | Doors | Solid Core/ Safety glass | Paint | Single leaf, observation panel | 920mm clear opening with intergral venetian or sliding panel; 1 - clean-up room & 1 - set-up/scrub rooms | |
2767 | Cornice | Plasterboard | Paint | Square set | ||
2000 | Skirting | Vinyl | Prefinished | Floor vinyl coved, 150mmH | ||
1620 | Wall Protection | Composite | Prefinished PVC | Corner Guards | near hand wash area | |
5020 | Ceiling | Plasterboard | Paint, scrub resistant | Flush set, suspended | ||
3010 | Wall finish | Paint | Scrub resistant |
ID | Description | Category | Group | Qty | Selection / Remarks |
1030 | Bench: resinate | Furniture/ Fitting | 1 | 1 | documentation station: computers, write-up |
1252 | Blind: Venetian integral | Furniture/ Fitting | 1 | 1 | to door glazing asrequired |
4350 | Cupboard: tall | Furniture/ Fitting | 1 | 1 | |
6152 | Dispenser: disposable glove | Furniture/ Fitting | 2 | 1 | |
6154 | Dispenser: paper/ hand towel | Furniture/ Fitting | 2 | 1 | to basin |
6158 | Dispenser: soap antiseptic | Furniture/ Fitting | 2 | 1 | to basin |
8291 | Air flowmeter | MEQ - General | 3 | 1 | to services pendant |
8297 | Bracket: suction bottle | MEQ - General | 2 | 3 | |
8306 | IV pole: mobile | MEQ - General | 3 | 2 | |
8309 | Oxygen flowmeter | MEQ - General | 3 | 2 | to services pendant |
8318 | Suction adapter | MEQ - General | 3 | 3 | to services pendant |
8321 | Suction bottle | MEQ - General | 3 | 3 | to services pendant |
8385 | Carrier stand, suction canisters | MEQ - General | 3 | 1 | |
8408 | Kick bucket | MEQ - General | 3 | 1 | |
8411 | Stool: adjustable, OR | MEQ - Furniture | 3 | 2 | |
8593 | Bracket: patient monitor | MEQ - General | 3 | 1 | for cardiac monitor mounted on service pendant. |
8594 | Linen carrier: dirty, single | MEQ - Furniture | 3 | 1 | |
8616 | Trolley: procedure | MEQ - Furniture | 3 | 1 | |
8620 | Trolley: instrument | MEQ - Furniture | 3 | 1 | |
8608 | Waste bin: clinical, 120 litres | MEQ - Furniture | 3 | 1 | |
8622 | Trolley: gowns | MEQ - Furniture | 3 | 1 | |
8982 | Stretcher: procedure/ recovery | MEQ - Furniture | 3 | 1 | |
10061 | Waste bin: General, 20 Litres | Furniture/ Fitting | 3 | 1 | |
108970 | Returntop: 2400x600 | Furniture/ Fitting | 3 | 1 |
ID | Description | Grp | Qty | Ele | Data | CdW | HtW | WmW | Tap | Dns | Gas | Selection / Remarks |
3100 | Basin: scrub, Type A | 1 | 1 | ___ | ___ | yes | ___ | yes | yes | yes | ___ | |
6468 | Camera: in room | 2 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | PTZ, optional, part of integration system |
8472 | Infusion pump: syringe | 3 | 2 | yes | opt | ___ | ___ | ___ | ___ | ___ | ___ | Qty TBC by project |
8473 | Infusion pump: rapid, blood/ solution warming, on stand | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | Qty TBC by project |
8548 | Light: surgical, single, ceiling, with two monitor arms & camera | 3 | 1 | yes | opt | ___ | ___ | ___ | ___ | ___ | ___ | light configuration may change depending on integration system requirements |
8786 | Supply unit: ceiling, double arm | 2 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | |
8966 | Monitor: video, medical grade, HD, 19-inch | 3 | 2 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | optional, control monitors part of integration system |
8485 | Monitor: physiologic, critical care | 3 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | |
8923 | Electrosurgical unit: argon enhanced coagulation, on stand | 3 | 1 | yes | opt | ___ | ___ | ___ | ___ | ___ | ___ | |
8967 | Monitor: video, medical grade, HD, 26-inch | 3 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | optional, display monitor part of integration system |
8970 | Monitor: video, medical grade, HD, 55-inch | 3 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | optional, wall mounted part of integration system |
8989 | Infusion pump: single channel | 3 | 2 | yes | opt | ___ | ___ | ___ | ___ | ___ | ___ | Qty TBC by project |
9222 | Control panel: surgical, recessed | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | includes slave analogue clock, elapsed time clock, temperature and humidity indicators and controls, IPS and UPS systems alarms, medical gas alarms, AGSS controls, theatre lamp controls, general lighting controls and power sockets as required |
9392 | Cabinet: endoscopes, drying, double door, pass-through | 2 | 1 | yes | opt | ___ | ___ | ___ | ___ | ___ | ___ | optional |
9453 | Endoscopy tower: upper & lower GI | 3 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | to include video imaging system (video processor, monitor and printer), light source integrated CO2/ air insufflation, suction pump, high frequency generator,endoscopes, optional equipment cart, and image and data acquisition and documentation system |
9922 | Pill cam: endoscopy | 3 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | optional |
10173 | Cabinet: server, OR integration | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | optional, part of integration system |
11400 | Computer: PC & monitor | 3 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | for nursing & medical staff documentation |
30120 | Integration system: endoscopy, HD | 3 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | optional, includes 1 display monitor and 1 control monitor in the surgical field, 1 control at the nurse workstation, and1 display monitor on the wal |
40404 | Tapware: sensor | 1 | 1 | yes | ___ | yes | yes | yes | ___ | ___ | ___ | straight spout |
54520 | Telephone: handset, handsfree | 3 | 1 | ___ | yes | ___ | ___ | ___ | ___ | ___ | ___ | on bench |
ID | Description | Service Category | Qty | Selection / Remarks |
2578 | PO: Emergency power, double | Power | 2 | to walls |
2726 | PO: UPS, double | Power | 2 | to nurse documentation station |
2726 | PO: UPS, double | Power | 2 | optional (part of integration system); to integration system server cabinet |
2757 | Direct connection: Uninterrupted power | Power | 1 | optional (part of integration system); to in room camera |
2757 | Direct connection: Uninterrupted power | Power | 2 | 1- surgical control panel, 1- operating light |
2756 | Cable conduit | Electrical | 1 | optional (part of integration system); for integration system server cabinet |
1006 | Voice / Data outlet: double | Communications | 1 | to nurse documentation station |
2024 | Music system | Communications | 1 | optional |
2760 | Direct connection: Voice/ Data | Communications | 2 | 1- in room camera (optional, part of integrationsystem), 1 - operating light camera attachment |
2760 | Direct connection: Voice/ Data | Communications | 1 | to surgical control panel (to be integrated with BMS & lighting controls) |
8090 | Orderly/ Porter call | Nurse Call | 1 | optional; to services pendant or wall panel |
2723 | PO: Cardiac Protected/IPS, single | Power | 8 | to services pendant |
2724 | Direct connection: Emergency power | Power | 2 | 1- services pendant; 1- sensor tap |
5005 | Air conditioning: special | HVAC | HEPA filtered; positive or negative pressure to be provided as per special room requirements | |
2576 | PO: Cleaner | Power | 1 | |
8080 | Emergency call | Nurse Call | 1 | + indicator button & light; to services pendant or wall panel |
8010 | Staff/ Nurse assist call | Nurse Call | 1 | + indicator button & light; to sevices pendant or wall panel |
7070 | Scavenge | Medical Gases | 1 | to services pendant |
7040 | Suction | Medical Gases | 3 | to services pendant |
1947 | Carbon Dioxide (CO2) | Medical Gases | 1 | optional central connection to services pendant |
7020 | Medical Air (MA) | Medical Gases | 1 | to services pendant |
7010 | Nitrous Oxide (N2O) | Medical Gases | 1 | to services pendant |
7000 | Oxygen (O2) | Medical Gases | 2 | to services pendant |
2242 | General LED: colour corrected | Lighting | variable lighting level | |
1006 | Voice / Data outlet: double | Communications | 2 | to services pendant |
1005 | Voice / Data outlet: single | Communications | 2 | 1- telephone; 1- endoscope drying cabinet (optional) |
1379 | Audio/ Video outlet | Communications | 4 | to services pendant |
6005 | Dimmable | Lighting | ||
1006 | Voice / Data outlet: double | Communications | 2 | optional (part of integration system); 1- 19" wall mounted control monitor, 1- 55" wall mounted display monitor (1 each) |
1006 | Voice / Data outlet: double | Communications | 2 | optional (part of integration system); 1- 19"control monitor and 1- 26" display monitor within the surgical field (1 each) |
1006 | Voice / Data outlet: double | Communications | 2 | to walls |
2761 | Direct connection: Tool Air | Medical Gases | 1 | to services pendant (for brakes) |
9030 | Cardiac protected/ IPS | Power | ||
2694 | PO: UPS, single | Power | 8 | to services pendant |
2726 | PO: UPS, double | Power | 2 | optional (part of integration system); 1- 19" wall mounted control monitor, 1- 55" wall mounted display monitor (1 each) |
2726 | PO: UPS, double | Power | 2 | optional (part of integration system); 1- 19" control monitor and 1- 26" display monitor within the surgical field (1 each) |
2726 | PO: UPS, double | Power | 2 | to walls |
2694 | PO: UPS, single | Power | 2 | optional; to loudspeaker and on-air lamp (part of integration system - refer to manufacturer's specifications) |
2728 | PO: Single phase, high current, 32 Amp | Power | 1 | optional, for laser on wall |
6074 | Special: 'Laser In Use' lights | Lighting | 1 | outside room entries, if laser is used (optional) |
1379 | Audio/ Video outlet | Communications | 2 | optional (part of integration system); 1- 19"control monitor and 1- 26" display monitor within the surgical field (1 each) |
1379 | Audio/ Video outlet | Communications | 2 | optional (part of integration system); 1- 19" wall mounted control monitor; 1- 55" wall mounted display monitor (1 each) |
7022 | Compressed air | Medical Gases | 1 | to endoscope drying cabinet (optional) |
2578 | PO: Emergency power, double | Power | 1 | to endoscope drying cabinet (optional) |
5037 | Special exhaust: dryer | HVAC | 1 | to endoscope drying cabinet (optional) |