A multipurpose room for interviews, consultation, staff meetings, teaching and training activities. This room may also function as a distressed relatives room for grieving relatives. The room may be located in close proximity to a Beverage Bay as required. An external outlook is desirable. Each unit should have access to a meeting room to support conference and interview functions and rooms may be shared between units.
Acoustics: Sound attenuation level - high; Acoustic privacy essential.
Additional Design Considerations:
- A second egress door may be required for staff safety and security. If this door swings out into a corridor, an alcove that is deeper than the width of the door must be provided.
Amendment
02.08.2019 First Draft
26.05.2023 RDS reviewed
Fabric and outline specifications
ID
Fabric
Material
Finish
Specification
Selection
Remarks
1219
Door Protection
Composite
Prefinished PVC
Kickplate, 300mm high
3000
Wall finish
Paint
Acrylic, washable
4159
Cornice
Aluminium
Powdercoat
Angle flush against wall, in line with ceiling grid
5062
Ceiling
Acoustic
Prefinished
Drop-in tiles, 600x600 mm
use set plasterboard ceiling for mental health applications
1088
Skirting
Timber
Paint
150mmH x 20mm thick nominal
MDF also acceptable; or floor vinyl coved skirting if vinyl is used
1144
Floor finish
Carpet
Synthetic
Carpet tiles
vinyl also acceptable
7001
Windows
desirable
9006
Doors
Solid Core/ Safety glass
Paint
Single leaf, observation panel
920mm clear opening, lockable, additional door may be required for staff access/ egress
Fittings and Furniture (FF)
ID
Description
Category
Group
Qty
Selection / Remarks
2100
Chair: ergonomic, office
Furniture/ Fitting
3
1
optional; provide if desk is provided
2600
Chair: visitor, office
Furniture/ Fitting
3
2
qty = 4 if desk not required
2899
Blind: roller
Furniture/ Fittings
1
1
to external window if provided; vertical blinds also acceptable