Print Download PDF Version
1 Bed Room - Standard, 18m2, Outboard Ensuite
Room Code
OFF-CEO-I
Net Room Area Briefed
15
Hours of Operation
8am to 6pm
Occupancy
Up to 5
Description / Special Requirements
An Office to be used by the CEO / General Manager to perform administrative duties and allows for confidential discussion in a degree of privacy. The room area includes an allowance for a small meeting area incorporated into the office. An external outlook is desirable.
Acoustics: Sound attenuation level - medium; Acoustic privacy required.
Amendment
24.10.10, - First Draft
21.04.11, - Room Fabric and Outline Specificaiton modified
Fabric and outline specifications
ID
Fabric
Material
Finish
Specification
Selection
Remarks
3000
Wall finish
Paint
Acrylic, washable
5060
Ceiling
Acoustic
Prefinished
Drop-in tiles, 600x1200
7001
Windows
Desirable
8000
Door protection
Vinyl
Prefinished
Kickplate, 300mm high
optional
6025
Cornice
Aluminium
Powdercoat
shadow line
949496
Skirting
Timber
Paint
150mmH x 20mm thick, nominal
1149
Floor finish
Carpet
90/10 Wool/ Nylon
Broadloom, 48 oz.
9001
Doors
Solid Core
Paint
Single leaf
920mm clear opening; lock set
Fittings and Furniture (FF)
ID
Description
Category
Group
Qty
Selection / Remarks
350
Artwork
Furniture/ Fitting
3
2
as required
1250
Blind: Venetian
Metalwork
3
1
to external window
1300
Bookcase
Furniture/ Fitting
3
1
2100
Chair: ergonomic, office
Furniture/ Fitting
3
1
Executive
2600
Chair: visitor, office
Furniture/ Fitting
3
4
3400
Coathook
Metalwork
1
2
4250
Credenza
Furniture/ Fitting
3
1
Executive; behind desk
5902
Desk: with conference end
Furniture/ Fitting
3
1
Executive
6000
Desk return
Furniture/ Fitting
3
1
Executive
24100
Waste bin: paper, 20 Litre
Furniture/ Fitting
3
1
Fixtures, Equipment and associated Services (FE)
ID
Description
Grp
Qty
Ele
Data
CdW
HtW
WmW
Tap
Dns
Gas
Selection / Remarks
11400
Computer: PC & monitor
3
1
yes
yes
___
___
___
___
___
___
54520
Telephone: handset, handsfree
3
1
___
yes
___
___
___
___
___
___
Services
ID
Description
Service Category
Qty
Selection / Remarks
1006
Voice / Data outlet: double
Communications
2
5000
Airconditioning
HVAC
6000
General fluorescent
Lighting
9001
GPO: Double
Power
3