Room Code | OR-HY-CT-I |
Net Room Area Briefed | 70 |
Hours of Operation | 24 Hours |
Occupancy | 1 patient; 5 - 12 staff |
Description / Special Requirements | The Operating Room - Hybrid - CT provides an aseptic environment in which to carry out surgical procedures under local, regional or general anaesthetic. The room will adjoin the CT Scanning Room. The CT Gantry will move between the OR and the CT on floor tracks. The Operating Room - Hybrid is used for surgical procedures that require large and bulky equipment, including Neurosurgery. Cardiac Protected electrical area Special Air Conditioning - HEPA filtration Additional Design Considerations: - Minimum critical dimension 6000mm on at least 1 side. - 'Laser In Use' warning lights may be required outside all exit doors to room if laser equipment is to be used - Lead shielding will be required; to be assessed by Radiation Consultant - External windows are desirable - double glazed with integral Venetian blinds - Provide isolated power supply individually to each large Operating Room, together with its associated line isolation and overload monitors |
Amendment | 10.03.2023 RDS updated 16.05.2024 Fabrics & Services updated |
ID | Fabric | Material | Finish | Specification | Selection | Remarks |
7025 | Observation | Lead glass | Clear | Internal window | to Control Room | |
2269 | Doors | Solid Core/ Lead glass | Paint | Double leaf, observation panel, lead shielding | clear opening to permit CT Gantry from adjoining CT room | |
2269 | Doors | Solid Core/ Lead glass | Paint | Double leaf, observation panel, lead shielding | 1600min clear opening to patient entry/ exit and scrub; obs panel with sliding cover or internal venetians | |
1000 | Floor finish | Vinyl | Standard slip resistant | Seamless, coved | ||
6015 | Cornice | Plasterboard | Paint | Flush coved between wall & ceiling | ||
8040 | Door protection | Composite | Prefinished PVC | To door frame | ||
5020 | Ceiling | Plasterboard | Paint, scrub resistant | Flush set, suspended | ||
8010 | Door protection | Composite | Prefinished PVC | Protection plate to 900mm AFFL | ||
2313 | Skirting | Vinyl | Prefinished | Floor vinyl coved, 300mmH | ||
3010 | Wall finish | Paint | Scrub resistant | epoxy paint or full height wall vinyl also acceptable | ||
9006 | Doors | Solid Core/ Safety glass | Paint | Single leaf, observation panel | 920mm clear opening to sterile stock room/ setup room, obs panel with sliding cover or integral venetians |
ID | Description | Category | Group | Qty | Selection / Remarks |
1030 | Bench: resinate | Furniture/ Fitting | 1 | 1 | documentation station: computers, write-up |
6152 | Dispenser: disposable glove | Furniture/ Fitting | 2 | 1 | |
8291 | Air flowmeter | MEQ - General | 3 | 2 | to services pendants |
8296 | Bowl stand: single | MEQ - General | 3 | 2 | |
8297 | Bracket: suction bottle | MEQ - General | 2 | 4 | |
8306 | IV pole: mobile | MEQ - General | 3 | 2 | |
8309 | Oxygen flowmeter | MEQ - General | 3 | 4 | to services pendants |
8318 | Suction adapter | MEQ - General | 3 | 4 | to services pendants |
8321 | Suction bottle | MEQ - General | 3 | 4 | |
8343 | Cabinet: storage, instrument, OR, double door, recessed | MEQ - Furniture | 2 | 1 | |
8385 | Carrier stand, suction canisters | MEQ - General | 3 | 1 | |
8398 | Trolley: resuscitation | MEQ - Furniture | 3 | 1 | |
8408 | Kick bucket | MEQ - General | 3 | 2 | |
8411 | Stool: adjustable, OR | MEQ - Furniture | 3 | 2 | |
8412 | Stool: adjustable, OR, with backrest | MEQ - Furniture | 3 | 1 | for anaesthetist |
8593 | Bracket: patient monitor | MEQ - General | 2 | 1 | for cardiac monitor, mounted on anaesthesia pendant |
8594 | Linen carrier: dirty, single | MEQ - Furniture | 3 | 2 | |
8603 | Headlight: surgical | MEQ - General | 3 | 1 | |
8620 | Trolley: instrument | MEQ - Furniture | 3 | 3 | |
8622 | Trolley: gowns | MEQ - Furniture | 3 | 1 | |
8627 | Trolley: anaesthetic | MEQ - Furniture | 3 | 1 | |
8630 | Table: mayo | MEQ - Furniture | 3 | 1 |
ID | Description | Grp | Qty | Ele | Data | CdW | HtW | WmW | Tap | Dns | Gas | Selection / Remarks |
6468 | Camera: in room | 2 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | PTZ, optional, part of integration system |
8472 | Infusion pump: syringe | 3 | 2 | yes | opt | ___ | ___ | ___ | ___ | ___ | ___ | Qty TBC by project |
8473 | Infusion pump: rapid, blood/ solution warming, on stand | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | Qty TBC by project |
8548 | Light: surgical, single, ceiling, with two monitor arms & camera | 2 | 1 | yes | opt | ___ | ___ | ___ | ___ | ___ | ___ | light configurations may change depending on OR integration system requirements |
8714 | Anaesthesia unit: standard | 3 | 1 | yes | opt | ___ | ___ | ___ | ___ | ___ | ___ | |
8767 | Defibrillator: with monitor | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | |
8786 | Supply unit: ceiling, double arm | 2 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | surgical pendant |
8822 | Warming cabinet: dual compartment, freestanding, 500L | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | optional |
8939 | Endoscopy tower: laparoscopy | 3 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | includes video processor, light source, insufflator, suction/ irrigator, high frequency generator (electrosurgical unit), smoke evacuator, monitor, endoscopes, and optional equipment cart |
8941 | Integration system: OR, HD | 2 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | optional, includes 2 display monitors and 1 control monitor in the surgical field, 2 display monitor on the wall, and 1 control monitor on the nurse workstation |
8953 | Hypo-hyperthermia unit: general | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | |
8966 | Monitor: video, medical grade, HD, 19-inch | 3 | 2 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | optional, control monitors part of integration system |
8967 | Monitor: video, medical grade, HD, 26-inch | 3 | 2 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | optional, display monitors part of integration system |
8970 | Monitor: video, medical grade, HD, 55-inch | 3 | 2 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | optional, wall mounted part of integration system |
8973 | Pump: suction/ aspirator, portable | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | |
8989 | Infusion pump: single channel | 3 | 2 | yes | opt | ___ | ___ | ___ | ___ | ___ | ___ | Qty TBC by project |
9023 | Tracking system: instrument tray | 3 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | optional, workstation part of CSSD instrument tracking system |
9222 | Control panel: surgical, recessed | 2 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | includes slave analogue clock, elapsed time clock, temperature and humidity indicators and controls, IPS and UPS systems alarms, medical gas alarms, AGSS controls, theatre lamp controls, general lighting controls and power sockets as required |
9547 | Medication dispensing system: automated, anaesthesia | 2 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | optional, quantity and modules depend on service requirements; with this option anaesthetic trolley may not be required |
9597 | Supply unit: ceiling, anaesthesia, tandem, double arm | 2 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | anaesthesia pendant |
10173 | Cabinet: server, OR integration | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | optional, part of integration system |
10389 | Light: surgical, single, ceiling, with monitor arm | 2 | 1 | yes | opt | ___ | ___ | ___ | ___ | ___ | ___ | light configurations may change depending on OR integration system requirements |
11400 | Computer: PC & monitor | 3 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | for nursing & medical staff documentation |
54520 | Telephone: handset, handsfree | 3 | 1 | ___ | yes | ___ | ___ | ___ | ___ | ___ | ___ | on bench |
8779 | Monitor: physiologic, operating theatre/ cardiac | 3 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | on anaesthesia pendant |
9067 | Operating table: mobile, electric, general | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | compatible with CT scanning unit |
9083 | Scanning unit: CT, 128-slice | 2 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | number of slices depends on service/ project requirements |
13363 | Pump: suction/ aspirator, surgical, mobile | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ |
ID | Description | Service Category | Qty | Selection / Remarks |
1006 | Voice / Data outlet: double | Communications | 2 | to nurse documentation station |
1005 | Voice / Data outlet: single | Communications | 2 | 1- telephone; 1- anaesthesia medication dispensing unit |
1379 | Audio/ Video outlet | Communications | 8 | for services pendants; 2- per anaesthetic arm, 4- surgical pendant |
1947 | Carbon Dioxide (CO2) | Medical Gases | 1 | 1- surgical pendant (optional) |
8010 | Staff/ Nurse assist call | Nurse Call | 1 | + indicator button & light; to anaesthesia pendant |
2024 | Music system | Communications | 1 | optional |
5005 | Air conditioning: special | HVAC | HEPA filtered | |
5040 | Pressure: positive | HVAC | ||
2242 | General LED: colour corrected | Lighting | variable lighting level | |
6074 | Special: 'Laser In Use' lights | Lighting | outside room entries, if laser to be used (optional) | |
7000 | Oxygen (O2) | Medical Gases | 4 | 1- per anaesthetic pendant arm; 2- surgical pendant |
7010 | Nitrous Oxide (N2O) | Medical Gases | 2 | 1- per anaesthetic pendant arm |
7020 | Medical Air (MA) | Medical Gases | 2 | 1- anaesthesia pendant; 1- surgical pendant |
7040 | Suction | Medical Gases | 4 | 1- per anaesthetic pendant arm; 2- surgical pendant |
7070 | Scavenge | Medical Gases | 2 | 1- per anaesthetic pendant arm |
8080 | Emergency call | Nurse Call | 1 | + indicator button & light; to anaesthesia pendant |
8090 | Orderly/ Porter call | Nurse Call | 1 | optional; to anaesthesia pendant |
2576 | PO: Cleaner | Power | 1 | |
9030 | Cardiac protected/ IPS | Power | ||
2723 | PO: Cardiac Protected/IPS, single | Power | 24 | for services pendants; 6- per anaesthetic arm, 12- surgical arm |
2724 | Direct connection: Emergency power | Power | 2 | for pendants |
2728 | PO: Single phase, high current, 32 Amp | Power | 1 | optional; for laser on wall |
1006 | Voice / Data outlet: double | Communications | 8 | to services pendants; 2- per anaesthetic arm, 4- surgical pendant |
2756 | Cable conduit | Electrical | 1 | optional (part of integration system); for integration system server cabinet |
2578 | PO: Emergency power, double | Power | 2 | for walls |
2578 | PO: Emergency power, double | Power | 2 | 1- resuscitation trolley; 1- warming cabinet (optional) |
2726 | PO: UPS, double | Power | 2 | for walls |
2760 | Direct connection: Voice/ Data | Communications | 2 | 1- in room camera (optional, part of integration system), 1 - operating light camera attachment |
2760 | Direct connection: Voice/ Data | Communications | 1 | for surgical control panel (to be integrated with BMS & lighting controls) |
2761 | Direct connection: Tool Air | Medical Gases | 2 | 1 per pendant (for brakes) |
2757 | Direct connection: Uninterrupted power | Power | 3 | 1- surgical control panel, 2- operating lights (1 each) |
2757 | Direct connection: Uninterrupted power | Power | 1 | optional (part of integration system); ; for in room camera |
2726 | PO: UPS, double | Power | 2 | for nurse documentation station |
2726 | PO: UPS, double | Power | 2 | optional (part of integration system); for integration system server cabinet |
2726 | PO: UPS, double | Power | 1 | optional; anaesthesia medication dispensing unit |
12011 | Radiation shielding | Shielding | for walls, floor, ceiling, doors & glazing as specified by Radiation Consultant | |
1006 | Voice / Data outlet: double | Communications | 3 | optional (part of integration system); 1- 19" wall mounted control monitor, 2- 55" wall monitors (1 each) |
1006 | Voice / Data outlet: double | Communications | 3 | optional (part of integration system); for 1- 19" control monitor and 2- 26" display monitors within the surgical field (1 each) |
2726 | PO: UPS, double | Power | 3 | optional (part of integration system); 1- 19" wall mounted control monitor, 2- 55" wall monitors (1 each) |
2726 | PO: UPS, double | Power | 3 | optional (part of integration system); for 1- 19" control monitor and 2- 26" display monitors within the surgical field (1 each) |
6005 | Dimmable | Lighting | ||
1006 | Voice / Data outlet: double | Communications | 2 | for walls |
6076 | Special: 'X-ray In Use' lights | Lighting | 1 | |
1040 | Intercom | Communications | 1 | handsfree to control room |
5743 | Trunking: 200mm x 100mm | Electrical Installations | 1 | between equipment room, control room and hydrid OR room |
11505 | Floor duct for power & data | Services Ducts | 1 | between equipment room, control room and hydrid OR room |
4030 | Drainage | Hydraulics | 1 | for safety drain through sink (if water condenses from Gantry); depending on the number of slices |
2792 | Clean Agent Gas Fire Suppression | Fire Services | 1 | |
2694 | PO: UPS, single | Power | 2 | optional; to loudspeaker and on-air lamp (part of integration system - refer to manufacturer's specifications) |
1379 | Audio/ Video outlet | Communications | 3 | optional (part of integration system); 1- 19" wall mounted control monitor, 2- 55" wall monitors (1 each) |
1379 | Audio/ Video outlet | Communications | 3 | optional (part of integration system); for 1- 19" control monitor and 2- 26" display monitors within the surgical field (1 each) |
6870 | Surgical Air (SA7) | Medical Gases | 2 | 2- surgical pendant |
6909 | Wave pad access | Security | 2 | to patient entry/ exit door |