Online Room Data Sheet |
---|
Room Code | BUT-1.5-I |
Net Room Area Briefed | 1.5 |
Hours of Operation | 24 Hours |
Occupancy | 1 |
Description / Special Requirements | The Utility Bay provides an area with a bench and sink for use as a preparation area. The bay may be located adjacent to patient treatment areas. The bay should be located in close proximity to a staff handwashing basin. |
Amendment | 24.10.2010 First Draft 18.08.2016 Services updated |
ID | Fabric | Material | Finish | Specification | Selection | Remarks |
2000 | Skirting | Vinyl | Prefinished | Floor vinyl coved, 150mmH | ||
3000 | Wall finish | Paint | Acrylic, washable | |||
4031 | Wall protection | Composite | Prefinished PVC | Corner guards to 1500 AFFL | other heights also acceptable as per project standardisation | |
5010 | Ceiling | Plasterboard | Paint, washable | Flush set, suspended | minimum height 2400mm; plasterboard drop in tile ceiling may also be used if bay is part of a larger zone | |
3052 | Wall finish | Vinyl | Prefinished | Wall vinyl to 1500mm AFFL | ||
1000 | Floor finish | Vinyl | Standard slip resistant | Seamless, coved | ||
6025 | Cornice | Aluminium | Powdercoat | shadow line |
ID | Description | Category | Group | Qty | Selection / Remarks |
1010 | Bench: stainless steel | Metalwork | 1 | 1 | with wet edge and inset sink, open under part |
6154 | Dispenser: paper/ hand towel | Furniture/ Fitting | 2 | 1 | to sink |
6156 | Dispenser: soap | Furniture/ Fitting | 2 | 1 | to sink |
19820 | Shelf: SS, under | Metalwork | 1 | 1 | under part bench |
20000 | Shelving unit: adjustable | Furniture/ Fitting | 1 | 1 | over bench |
24100 | Waste bin: paper, 20 Litre | Furniture/ Fitting | 3 | 1 | under bench |
ID | Description | Grp | Qty | Ele | Data | CdW | HtW | WmW | Tap | Dns | Gas | Selection / Remarks |
47800 | Sink, SS: single in bench | 1 | 1 | ___ | ___ | yes | opt | opt | yes | yes | ___ | warm water if located in a patient accessible area; with wall mounted lever taps |
ID | Description | Service Category | Qty | Selection / Remarks |
4033 | Floor waste | Hydraulics | 1 | |
5000 | Airconditioning | HVAC | consistent with adjacent area | |
1983 | General fluorescent: downlights | Lighting |