Edit it in Health Facility Briefing System (HFBS) | |||
---|---|---|---|
Edit this room data or print a PDF using the HFBS - Health Facility Briefing System. Customise this room data for your project, or add it to an existing health facility brief in HFBS Briefing Module. | Edit Briefing |
Room Layout Sheet | |||
---|---|---|---|
Download a PDF Room Layout Sheet (RLS) for this standard component. | Free | View |
Other Files | |||
---|---|---|---|
Buy an edible Revit Room Layout Sheet (RLS) for this standard component. | $64.99 |
Online Room Data Sheet |
---|
Room Code | CLREC-I |
Net Room Area Briefed | 9 |
Hours of Operation | 8am to 8pm, Monday to Friday |
Occupancy | 1-2 intermittently |
Description / Special Requirements | A room for clerical activities including record sorting and secure storage of medical records. The photocopier, facsimile and printer may also be located in this area if required. |
Amendment | 24.10.2010 First Draft 05.05.2011 Fabric, FF & Services modified 18.04.2023 RDS updated. |
ID | Fabric | Material | Finish | Specification | Selection | Remarks |
3000 | Wall finish | Paint | Acrylic, washable | |||
4159 | Cornice | Aluminium | Powdercoat | Angle flush against wall, in line with ceiling grid | ||
1088 | Skirting | Timber | Paint | 150mmH x 20mm thick nominal | MDF also acceptable; or floor vinyl coved skirting if vinyl is used | |
5062 | Ceiling | Acoustic | Prefinished | Drop-in tiles, 600x600 mm | ||
1219 | Door Protection | Composite | Prefinished PVC | Kickplate, 300mm high | ||
9001 | Doors | Solid Core | Paint | Single leaf | ||
1144 | Floor finish | Carpet | Synthetic | Carpet tiles | vinyl also acceptable |
ID | Description | Category | Group | Qty | Selection / Remarks |
1050 | Bench: laminate | Furniture/ Fitting | 1 | 1 | |
4420 | Cupboard: under bench, lockable | Furniture/ Fitting | 1 | 1 | adjustable shelves; paper storage |
13661 | Metal shelving: medical records | Furniture/ Fitting | 3 | 2 | |
20000 | Shelving unit: adjustable | Furniture/ Fitting | 1 | 1 | over bench |
ID | Description | Grp | Qty | Ele | Data | CdW | HtW | WmW | Tap | Dns | Gas | Selection / Remarks |
39800 | Photocopier | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | optional |
41100 | Printer: networked | 3 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | optional |
ID | Description | Service Category | Qty | Selection / Remarks |
1006 | Voice / Data outlet: double | Communications | 3 | |
5000 | Airconditioning | HVAC | ||
5019 | Exhaust | HVAC | over photocopier | |
2189 | General LED | Lighting | ||
2577 | PO: Double | Power | 3 |